15.8 Odor Cut control
This control starts when Cool / Soft Dry Mode ON and indoor fan speed is Auto.
The Auto fan pattern during this control.
LoLoOFFLoOFFLoLoLoOFF Softdry
MeLoOFF LoOFFLoHiLoOFFCool
AC fan
motor
DC fan
motor
SLoSSLoOFFSSLoOFFSSLoSLoSSLoOFF Softdry
AutoSSLoOFF SSLoOFFSSLoAutoSSLoOFFCool
LoLoOFFLoOFFLoLoLoOFF Softdry
MeLoOFF LoOFFLoHiLoOFFCool
AC fan
motor
DC fan
motor
SLoSSLoOFFSSLoOFFSSLoSLoSSLoOFF Softdry
AutoSSLoOFF SSLoOFFSSLoAutoSSLoOFFCool
Thermostat &
Compressor
Indoor fan
ON
OFF
40 sec 50 sec - 20 sec 120 sec 20 sec 40 sec 50 sec -
Thermostat &
Compressor
Indoor fan
ON
OFF
40 sec 50 sec - 20 sec 120 sec 20 sec 40 sec 50 sec -
During freeze prevention control, this control is not triggered.
15.9 Drain Pump Control
This control applicable for 95 x 95 Cassette and 60 x 60 Cassette indoor units only.
During the unit is operating Cool / Soft Dry Mode
(A) When compressor starts within 10 seconds
(B) When compressor starts after 10 seconds
(C) When thermostat OFF
During the unit in deice operation