1
1-267
unit : kW
Model
Power
Source
Ambient
Return
Air
DB TC IPT TC IPT TC IPT TC IPT TC IPT
16 6.4 1.81 6.6 1.82 7.6 1.81 7.7 1.72 7.7 1.61
20 6.1 1.86 6.3 1.87 7.0 1.84 7.0 1.75 7.0 1.64
24 5.8 1.92 5.9 1.93 6.3 1.87 6.3 1.78 6.3 1.67
16 7.3 2.30 7.5 2.32 8.6 2.29 8.8 2.14 8.8 1.97
20 7.0 2.37 7.2 2.39 8.0 2.32 8.0 2.17 8.0 2.00
24 6.6 2.44 6.8 2.46 7.2 2.37 7.2 2.22 7.2 2.04
16 11.6 2.94 11.6 2.80 11.6 2.57 11.6 2.39 11.6 1.89
20 11.2 3.04 11.2 2.91 11.2 2.68 11.2 2.49 11.1 2.00
24 10.7 3.15 10.7 3.02 10.8 2.79 10.8 2.60 10.7 2.10
16 13.9 3.76 14.4 3.65 14.6 3.51 14.6 3.20 14.5 2.49
20 13.3 3.90 13.9 3.79 14.0 3.66 14.0 3.35 13.9 2.64
24 12.8 4.05 13.3 3.94 13.4 3.81 13.4 3.49 13.4 2.79
16 16.7 4.55 16.7 4.54 16.6 4.45 16.6 3.87 16.6 3.20
20 16.0 4.74 16.0 4.72 16.0 4.64 16.0 4.06 15.9 3.38
24 15.4 4.92 15.4 4.91 15.4 4.83 15.4 4.25 15.3 3.57
S-71PT1E5
U-71PE1E5
(U-71PE1E8)
230V
240V
50Hz
1phase
(3 phase)
230V
240V
50Hz
1phase
S-140PT1E5
U-140PE1E5
(U-140PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-100PT1E5
U-100PE1E5
(U-100PE1E8)
230V
240V
50Hz
1phase
(3 phase)
S-125PT1E5
U-125PE1E5
(U-125PE1E8)
230V
240V
50Hz
1phase
(3 phase)
15㷄
S-60PT1E5
U-60PE1E5
Outdoor air intake temp(㷄䇭W.B.䋩
-5㷄 0㷄 6㷄 10㷄
● Combination of Single Unit
2. Heating Capacity Performance Data
Ceiling Type
1-12. Capacity Table
TC :Cooling Capacity
IPT :Cooling Power Consumption
SM830211-02PAC-i.indb267SM830211-02PAC-i.indb267 2012/07/1713:57:152012/07/1713:57:15