1-1. Unit Specifi cations
PEY1
4. Low Silhouette Ducted Type S-140PF1E5A / U-140PEY1E8
INDOOR MODEL S-140PF1E5A
PANEL MODEL
OUTDOOR MODEL U-140PEY1E8
Branch pipe MODEL -
PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN12102
POWER SUPPLY
ø, Hz 1ø 50Hz 3ø 50Hz
V 220 230 240 380 400 415 Min Max
C
O
O
L
I
N
G
CAPACITY
kW 14.0 14.0 14.0 3.3 15.5
BTU/h 47800 47800 47800 11300 52900
CURRENT A 1.55 1.50 1.47 6.75 6.45 6.25 - -
INPUT POWER
W 225 225 225 4.125k 4.125k 4.125k - -
TOTAL W - 4.350k 4.350k 4.350k 840 6.000k
ANNUAL CONSUMPTION
TOTAL kWh
*
4 - - 2175 - - -
EER/EER CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.22 3.22 / A 3.22 3.93 2.58
Erp
*
6
Pdsign kW ------
SEER (W/W) ------
Annual consumption
kWh------
Class ------
POWER FACTOR % - - - 93 92 92 - -
NOISE INDOOR
(H/M/L)
dB-A 40/36/33 -
Power Level dB 62/58/55 -
NOISE OUTDOOR
(H/L)
dB-A 54/-
Power Level dB 71/-
H
E
A
T
I
N
G
CAPACITY
kW 14.0 14.0 14.0 4.1 16.0
BTU/h 47800 47800 47800 14000 54600
CURRENT A 1.55 1.50 1.46 5.60 5.40 5.20 - -
INPUT POWER
W 225 225 225 3.355k 3.355k 3.355k - -
TOTAL W - 3.580k 3.580k 3.580k 900 5.200k
COP/COP CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.91 3.91 / A 3.91 4.56 3.08
Erp
*
6
Pdsign kW ------
Tbivalen °C ------
SCOP (W/W) ------
Annual consumption
kWh------
Class ------
POWER FACTOR % - - - 91 90 90 - -
NOISE INDOOR
(H/M/L)
dB-A 40/36/33 - ⁄ ⁄
Power Level dB 62/58/55 -
NOISE OUTDOOR
(H/L)
dB-A - 53/- ⁄ ⁄
Power Level dB - 70/-
EXTRA LOW TEMP
Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W) 1.91/285 1.86/285 1.81/285 10.0/6.200k 10.0/6.500k 10.0/6.750k ⁄
STARTING CURRENT(A)/COMP OUTPUT(W) - - - 6.75/3.0k 6.45/3.0k 6.25/3.0k⁄
NETWORK IMPEDANCE (ΩMAX.) - -
FM OUTPUT (W) 200 90×2 ⁄
MOISTURE REMOVAL VOLUME L/h(Pt/h) 9.0 (18.9) -
External static pressure
Pa
100 (MIN10 - MAX150)
I/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 36/32/25 (1271/1130/883)
HEAT m
3
/min (ft
3
/min) 36/32/25 (1271/1130/883)
O/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 135 (4767)
HEAT m
3
/min (ft
3
/min) 120 (4238)
REFRIGERANT TYPE, AMOUNT
g
(oz) R410A 3.40k (119.9) /
P
R
O
D
I
M
HEIGHT : H mm(inch) 290 (11-13/32) 1416 (55-3/4) /
WIDTH : W mm(inch) 1400 (55-1/8) 940 (37-1/32) /
DEPTH : D mm(inch) 700 (27-9/16) 340 (13-13/32) /
P
A
C
D
I
M
HEIGHT : H mm 355 1556 /
WIDTH : W mm 1614 1055 /
DEPTH : D mm 850 485 /
MASS
(NET) k
g
(lb) 45 (99) 98 (216) /
(GROSS) k
g
(lb) 54 (119) 108 (238) /
LAYERS LIMIT (actually) 9 (10) 1 (2)
Operation
Condition
Cool O.D(DBT) 18°C ~ 32°C -10°C ~ 43°C
Heat O.D(DBT) 16°C ~ 30°C -15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl ared type, 5.0(16.4) fl ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50 (16.4 ~ 164.0) ~ ~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher) (49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50 (0.538)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30 (98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:
SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.