26
7.9. Heat insulator and grand wire A assy
1. Remove the bind wires A of the lead wires.
2. Move the non-flammable tubes A and C and disconnect
the 2 faston terminals from the heater.
3. Remove the screw and detach the heat insurator.
4. Remove the screw, spring washer and hexagon nut and
detach the thermal fixing plate.
5. Detach the fitting plate of the grand wire A assy from the
heater while holding it with a long nose plier.
6. Remove the screw and detach the grand wire A assy from
the angle.
Tips on assembling
• Insert the thermal fixing plate notch position into the fixing
square hole of the heat insulator and screw the thermal fix-
ing plate on the heat insulator.
• Insert the positioning projection of the angle into the locator
hole of the heat insulator and screw the heat insulator to the
body.
• Make sure that the lead wire is protected by non-flammable
tubes A and C when connecting the faston terminal to the
heater.