12 The exchange method of pan sensor and thermal fuse
1 Remove the cast heater
•
To remove the cast heater, please refer to “The exchange method of cast heater” (Item 1 to 3, P16).
2 Remove pan sensor
•
Loosen and stretch out the claws (3 places) and take out
the pan sensor.
NOTES:
•
Care must be taken to avoid the spring for sensor from
deformation when removing.
3 Exchange thermal fuse
•
The replacement of pan sensor is the exchange of thermal fuse A/B.
This is because the thermal fuse A/B are both fi xed within the pan sensor.
4 Reassembly
•
Reassemble the new pan sensor in reverse order for disassembly.
NOTES:
•
Care must be taken to avoid the spring for sensor from deformation when reassembling.
•
Care must be taken to avoid the spring for sensor from tilting when reassembling.
•
Refer to P5 for wiring connection.
•
Please note the direction of pan sensor.
claws (3 places)
Thermal Fuse B
Thermal Fuse A
Thermistor
IP3830_SR-DF101_Eng_19_121224.in章节1:25 章节1:25 2012-12-24 17:19:46