EasyManua.ls Logo

Panasonic TC-14Z99M - 2.7 PAL Colour Output Level Adjustment

Panasonic TC-14Z99M
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.7. PAL Colour Output Level Adjustment
1. Receive the PAL B/G studio colour bar pattern and adjust local frequency at the best tuned position.
2. Pic Menu: Dynamic Normal, Confirm Contrast - 100 DAC, Sub Contrast - 21 dac.
3. Channel colour set --------- STD
4. “CHK2 and press digit key “5” (AKB OFF) also confirm OSD become blue colour.
5. Connect TPA 10 to TPA 20.
6. Set (A) to 2.3 ± 0.2V by BRT (CHK2) at measurement point TPL 2 Fig. 4.
1. Connect oscilloscope probe to TPL 2 (G OUT) with 10k
series resistor and adjust Contrast so that (B) as in Fig. 4 is 2.25 ±
0.05V.
2. Adjust “Sub Colour” so that waveform as in Fig. 4 (1) 2.5 ± 0.1V.
3. Connect oscilloscope probe to TPL 1 (R OUT) with 10k
series resistor and confirm waveform as in Fig. 5 is (2) 2.50 ± 0.4V.
4. Press digit key “5” (AKB ON) and confirm the OSD become white colour.
7