9 Adjustment Procedure
9.1. Driver Set-up
9.1.1. Item / Preparation
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture adjustment items as follows.
· Picture menu : Standard
· Color temperature : Normal
· Picture : 25
· Aspect : Full
Caution
1. First perform Vsus voltage adjustment.
2. Confirmation of Vscn voltage should be performed after confirmation of Vad voltage adjustment.
When Vad = -85V, Voltage of Vscn is 55V ± 4V.
9.1.2. Adjustments
Adjust driver section voltages.
(Refer to the panel data on the panel label)
Check or adjust the following voltages with the multimeter.
Name Test Point Voltage Volume Remarks
Vsus TPVSUS (SS) Vsus ± 0.5V VR251 (P_SS side) *
Vsus TPVSUS (SC) Vsus ± 0.5V VR251 (P_SC side) *
Ve TPVE (SS) Ve ± 1V VR6000 (SS) *
Ve2 TPVE2 (SS) 5±1V (Fixed)
Vad TPVAD (SC2) -85V ± 1V VR6600 (SC2)
Vscn TPVSCN (SC2) Vad + 140 ± 4V VR6605 (SC2)
Vset TPVSET (SC2) 240 ± 1V VR6604 (SC2)
Vset2 TPVSET2 (SC) Vad + 8 + 1V, -0V VR6603 (SC)
Vbk TPVBK (SC2) 150 ± 1V VR6351 (SC2)
Vda TPVDA (DR1) 75 ± 1V (Fixed) (P_SC side)
Vda TPVDA (DR2) 75 ± 1V (Fixed) (P_SC side)
Vda TPVDA (DR1) 75 ± 1V (Fixed) (P_SS side)
Vda TPVDA (DR2) 75 ± 1V (Fixed) (P_SS side)
Vc TPVC (DR1) 45 ± 0.5V VR600 (DR1_SC)
Vc TPVC (DR2) 45 ± 0.5V VR650 (DR2_SC)
Vc TPVC (DR1) 34.5 ± 0.5V VR600 (DR1_SS) D6 connector
should be
attached.
Vc TPVC (DR2) 34.5 ± 0.5V VR650 (DR2_SS) D16 connector
should be
attached.
*See the Panel label.
56