Initialization Pulse Adjustment
Item / Preparation
Input a Crosshatch signal.
Set the picture mode to Normal, and White Balance to Normal
Adjustments
Adjust the indicated test point for the specified waveform. Use test point TPSS1 of the
SS board as the trigger source.
Test point Volume Level Remark
--- 10 + 10 / -5µ Sec TH-42PX500U
T1
TPSC1 (SC)
--- 20 ± 15µ Sec TH-50PX500U
VR6557
(SC)
210 ± 10µ Sec TH-42PX500U
T2
TPSC1 (SC)
VR6602
(SC)
155 ± 10µ Sec TH-50PX500U
Table 11
Drive Waveform
Figure 52