EasyManua.ls Logo

Panasonic TH-65PF10WK - Page 32

Panasonic TH-65PF10WK
191 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TH-65PF10WK/TK
32
9.1.2. Initialization Pulse Adjust
1. Input a white signal pattern to plasma video input.
Aging pattern : 1
2. Set the picture adjustment items as follows.
Picture menu : Standard
Color temperature : Normal
Picture : 25
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 160 ± 10µ Sec.
9.1.3. P.C.B. (Printed Circuit Board) exchange
9.1.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
9.1.3.2. Quick adjustment after P.C.B. exchange
*See the Panel Label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
Test point Volume Level
T2 TPSC1 (SC) VR6602 (SC) 160 ± 10µ Sec.
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS Vsus ± 2V VR251 (P) *
SC Board Vad TPVAD -90V ± 1V VR6600 (SC)
Vscn TPVSCN Vad + 140V ± 4V Fixed
Vset TPVSET 240V ± 7V Fixed
SS Board Ve TPVE Ve ± 1V VR6000 (SS) *
Vda TPVDA 72V + 1V, -3V Fixed
D, DS Board White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board Set Market Select Number to correct destination by Ms mode (See chap. 6.1.4)

Table of Contents