8.3. A/D converter gain adjustment (480p . 1080i)
Preparation
PICTURE:VIVID (NORMAL SET)
ADJUSTMENT DATA: BRIGH, CONT
Note:
Set ABL operation to off in Contrast adjustment.
Measurement Instrument Remarks
1. Oscilloscope
2. Alignment equipment
Extension cable kit (Part No.TZSC0704)
3. Remote control
Picture menu: VIVID
Picture pattern: Studio color bar
Probe: The signal should be terminated by 75W, ±1% resistor.
Not use Cross hatch signal
Adjustment Procedures
1. Apply the 10 stair-step (B/W) signal (480p or 480i) to HDMI input.
2. Connect the Oscilloscope to CN3303-A38 (G out of DR-Board).
3. Adjust ADC-G so that the B-W (Blanking portion-White) is 0.53V±0.02V.
4. Also connect the oscilloscope to CN3303-A34 and observe both waveforms simultaneously.
5. Adjust ADC-R so that the amplitude of R signal waveform is same as G signal.
6. Connect the Oscilloscope to CN3303-A38 (G out) and CN3303-A36 (B out), and observe both waveforms simultaneously.
7. Adjust ADC-B so that the amplitude of B signal is same as G signal.
8. Apply 1080i 10 stair-step (B/W) signal to HDMI input.
9. Perform same procedures (item 2-7) as 480p signal adjustment.
15