*1 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
●A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered.
A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option output (A contact), select a device
that meets the following guidelines:
●Electric lock connection terminal (S1/S2, S3/S4):
--N/O dry closure contact
-- 12 V AC/DC, less than 1 A
●Connection device for option output (A contact) terminal (OUT1/OUT2):
-- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)
Wiring run
Wire type*1
Diameter Length (Max.)
Main Monitor Station –
Door station
A
φ 0.65 mm 22 AWG 100 m
φ 1.0 mm 18 AWG 130 m
φ 0.5 mm CAT 5 50 m
Main Monitor Station –
Power Supply Unit
B
φ 0.65 mm 22 AWG 10 m
φ 1.0 mm 18 AWG 20 m
Power Supply Unit –
AC power source
C
φ 1.2 mm - φ 2.0 mm
(17 AWG - 12 AWG)
No requirement
Door Station –
Electric Lock
*2
D
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
According to specification
of connected device.
Main Monitor Station -
Connection device for option
output (A contact)
*2
E
φ 0.5 mm - φ 1.2 mm
(24 AWG - 17 AWG)
According to specification
of connected device.
VL
VL
-
-
SWD501EX wiring type and length