37
Setting Options / DisplayDefault SettingMenu
5.6
Buffer tank connection
To connect tank to the system
and if selected YES, to set
T temperature.
The optional PCB connectivity
must be selected YES to
enable the function.
If the optional PCB
connectivity is not selected,
the function will not appear on
the display.
No
Yes
5 °C
Set
T for Buffer
Tank
5.7
Base pan heater
To select whether or not
optional base pan heater is
connected.
* Type A - The base pan heater
activates only during
deice operation.
* Type B - The base pan heater
activates when outdoor
ambient temperature is
5 °C or lower.
No
Yes
A
Set base pan heater
type*.
5.8
Alternative outdoor sensor
To select an alternative outdoor
sensor.
No
5.9
Bivalent connection
To select to enable or disable
bivalent connection.
No
Yes
To select either auto control
pattern or SG ready input
control pattern.
* This selection only display
to select when optional pcb
connection set to Yes.
Auto

Table of Contents