Disconnect the plug from the receptacle.
Remove the M4X8 machine screw.
Press the hook and slide the adapter out of
the fan body.
WARNING
1. Disconnect power supply
before installing the unit.
2. Please wear gloves to protect
hands during the installation.
ATTENTION
Remove the tape and accessory from the adapter, before installation.
Adapter
Tape
Damper
4” reducer (Not applicable
for FV-1115VK3)
Duct tape
INSTALLATION (CEILING MOUNTING)
Align
Joist
Bend down 4 tabs and align bracket to the joist.
Align and install bracket to joist by using
the 2 pre-installed tapping screws.
Extend bracket to the other joist.
Install bracket to joist by using 2 pre-installed
tapping screws.
The Flex-Z Fast bracket position can be adjusted from 16" to 24" between joists.
Install Flex-Z Fast bracket
Remove junction box cover
and secure conduit or stress
relief to junction box knock-out hole.
Install the circular exhaust duct
and secure it with clamps or ties
and seal it with mastic or approved
foil tape. A 4 or 6 inch circular
duct is needed to connect to
the relevant part of the adapter.
Install the adapter to Flex-Z Fast bracket
by using 2 self-drilling screws.
Install circular exhaust duct
Knock-out hole
Junction
Box cover
Conduit
Circular
exhaust duct
Mastic or
approved
foil tape
2 Self-drilling screws
Joist
2 Tapping screws
(ST4.2 X 20)
EXTEND
2 Tapping screws
(ST4.2 X 20)
Flex-Z Fast bracket
Remove adapter plate
Screw
®
®
®
®
Adapter
Machine screw (M4X8)
Guide Parts
Fan body
Hook
PRESS
Plug
Receptacle