IMPORTANT SAFETY INFORMATION
NOTICE
CAUTION
Make sure that the electric service supply voltage is AC 120V, 60Hz.
Do not disassemble the unit for reconstruction. It may cause fire or electric shock.
Install the fan at least 1.5 m (5 feet) above the floor.
Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C).
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
Occupation Safety and Health Act (OSHA), using UL approved wire nuts.
Do not kink the supply wiring.
The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are
provided.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
Provide make up air for proper ventilation.
Do not install the unit where ducts are configured as shown (Fig. B).
Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the
unit may not function.
Do not install fan above or inside 45-degree angle projected outwards from the cooking equipment element
closest to fan (Fig. A).
Please wear gloves to protect hands during installation.
Floor
45°
45°
Cooking
equipment
Fig. A
(Cooking area)
Do not install above or
inside this area
-Squeezed duct
-Successive bending -Excessive bending
Fig. B
-Bend close to duct adaptor