47
ALARM DATA
Specifies alarm transmission mode depending on the protocol selected by the 8-bit DIP switch.
POLLING: Transmits the alarm data in response to requests from the controller.
AUTO 1: Transmits the alarm data each time an alarm signal is received in the camera.
AUTO 2 (Default): Transmits alarm data at intervals of at least 5 seconds.
DELAY TIME
Specifies the time to transmit the acknowledge request when communicating on a 2-line connection.
(OFF, 10, 20, 40, 100 ms) Default : OFF.
This menu appears only when a 2-line communication is used. Make sure to be 100 ms when connecting
the camera with the WJ-FS616 Video Multiplexer or Matrix Switcher WJ-SX350 in a 2-line communication
system.
The settings become effective with the closing of the SET UP MENU.
Note: Set the same parameters for the cameras, controllers and personal computers in an RS485 chain.