EasyManua.ls Logo

Parker 590 series - Page 105

Parker 590 series
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Your Application 6-15
590 Series DC Digital Converter
I DMD. ISOLATE
Range: ENABLED/DISABLED
Speed loop bypass; the current demand is taken from ANIN 2 (A3).
The simplified diagram below shows how the I DMD ISOLATE parameter selects the controlling
loop.
SPEED LOOP PI
CURRENT LOOP PI
Speed Demand
Speed Feedback
Analog I/P2 (A3)
Digital I/P3 (C8)
I DMD ISOLATE
Current Demand
Current Feedback
Motor
shown ENABLED
+
-
+
-
AUTOTUNE
Range: ON/OFF
This is the autotune function trigger input.
ILOOP SUSPEND
Reserved parameter for use by Parker SSD Drives.
AT CURRENT LIMIT
Refer to the DIAGNOSTICS function block description, page 6-
18.
CURRENT FEEDBACK
Refer to the DIAGNOSTICS function block description, page 6-
18.
CURRENT DEMAND
Refer to the DIAGNOSTICS function block description, page 6-
18.

Table of Contents

Other manuals for Parker 590 series

Related product manuals