6-16 Programming Your Application
590 Series DC Digital Converter
Functional Description
TAG#
PARAMETER
DEFAULT
SETTING
137
DISCONTINUOUS
16
16
17
201
AUTOTUNE
PROP.GAIN
INT. GAIN
REGEN MODE
OFF
45.00
3.50
12.00
ENABLED
30
ADDITIONAL DEM
0.00%
10+
10-
299
67
66
61
ACTUAL
POS I LIM
D:8
CURRENT
DEMAND
ACTUAL
NEG
I LIM
D:9
D:4
NOTE (1)
119 IDMD. ISOLATE DIGITAL I/P 3
CURRENT LIMIT
SWITCH
PROGRAM STOP
SELECTS PROG STOP
I LIM SET IN
"STOP RATES" MENU
90 BIPOLAR CLAMPS
DIGITAL I/P 1
48
NEG I CLAMP
ANALOG I/P 4
15
CUR. LIMIT/SCALER 100.00%
301
POS. I CLAMP
ANALOG I/P 5
421
MAIN CURR. LIMIT 200.00%
-1
88
87
D:7
NEG I
CLAMP
D:6
POS I
CLAMP
+
+
DRIVE
ENABLED
P1
PHASE
ANGLE
CONTROL
42
D:11
AT CURRENT
LIMIT
D:5 CURRENT
FEEDBACK
298
65
ARMATURE CURRENT
FROM CALIBRATION BOARD
A6
ANALOG I/P 5
A5
ANALOG I/P 4
C6
ANALOG I/P 1
C8
ANALOG I/P 3
FROM
ANALOG
I/P 2
FROM
SPEED
LOOP
CURRENT LOOP
FROM
CURRENT
PROFILE
FROM
INVERSE TIME
OVERLOAD
NOTE (2)
Note 1: IDMD isolate removes speed loop demand and selects analog I/P 2 as current
regulator demand.
IDMD isolate is overridden by program stop and stop to return drive to speed
regulation.
Note 2: Regen mode disable prevents negative current demand. Non-regenerative drives
should have regen mode disabled.