Programming
Page D-188 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
B
C
D
1
2
3
4
5
6
7
E
100.01 RAMP TYPE REFERENCE RAMP ENUM 0 : LINEAR
1 : S
LINEAR rw
100.02 ACCEL TIME REFERENCE RAMP REAL 0.0 to 3000.0 s 10.0 s rw 3
100.03 DECEL TIME REFERENCE RAMP REAL 0.0 to 3000.0 s 10.0 s rw 3
100.04 SYMMETRIC MODE REFERENCE RAMP BOOL 0 : FALSE
1 : TRUE
FALSE rw
100.05 SYMMETRIC TIME REFERENCE RAMP REAL 0.0 to 3000.0 s 10.0 s rw 3
100.06 SRAMP
CONTINUOUS
REFERENCE RAMP BOOL 0 : FALSE
1 : TRUE
TRUE rw
100.07 SRAMP ACCEL REFERENCE RAMP REAL 0.00 to 100.00 /s^2 10.00 /s^2 rw
100.08 SRAMP DECEL REFERENCE RAMP REAL 0.00 to 100.00 /s^2 10.00 /s^2 rw
100.09 SRAMP JERK 1 REFERENCE RAMP REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.10 SRAMP JERK 2 REFERENCE RAMP REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.11 SRAMP JERK 3 REFERENCE RAMP REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.12 SRAMP JERK 4 REFERENCE RAMP REAL 0.00 to 100.00 /s^3 10.00 /s^3 rw
100.13 HOLD REFERENCE RAMP BOOL 0 : FALSE
1 : TRUE
FALSE rw
100.14 RAMPING REFERENCE RAMP BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
101.01 REMOTE SETPOINT REFERENCE REAL -300.00 to 300.00 % 0.00 % rw
101.02 SPEED TRIM REFERENCE REAL -300.00 to 300.00 % 0.00 % rw
101.03 MAX SPEED CLAMP REFERENCE REAL 0.00 to 110.00 % 110.00 % rw
101.04 MIN SPEED CLAMP REFERENCE REAL -110.00 to 0.00 % -110.00 % rw
101.05 TRIM IN LOCAL REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE rw
101.06 REMOTE REVERSE REFERENCE BOOL 0 : FALSE
1 : TRUE
FALSE rw
101.07 COMMS SETPOINT REFERENCE REAL -300.00 to 300.00 % 0.00 % rw 1
101.08 MAX SPEED REFERENCE REAL 0 to 32000 RPM 1500 RPM rw 4
101.09 SPEED DEMAND REFERENCE REAL _.xx 0.00 % ro Output
101.10 SPEED SETPOINT REFERENCE REAL _.xx 0.00 % ro Output