E
PREF Name Block Type Range Default ro\rw Notes
67.02 FORMULA DISPLAY SCALE 3 ENUM 0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C rw
67.03 COEFFICIENT A DISPLAY SCALE 3 REAL -32768.0000 to 32767.0000 1.0000 rw
67.04 COEFFICIENT B DISPLAY SCALE 3 REAL -32768.0000 to 32767.0000 1.0000 rw
67.05 COEFFICIENT C DISPLAY SCALE 3 REAL -32768.0000 to 32767.0000 0.0000 rw
67.06 HIGH LIMIT DISPLAY SCALE 3 REAL -32768.0000 to 32767.0000 0.0000 rw
67.07 LOW LIMIT DISPLAY SCALE 3 REAL -32768.0000 to 32767.0000 0.0000 rw
67.08 UNITS DISPLAY SCALE 3 STRING max length is 6 chars rw
68.01 DECIMAL PLACE DISPLAY SCALE 4 ENUM 0 : DEFAULT
1 : X.XXXX
2 : X.XXX
3 : X.XX
4 : X.X
5 : X.
DEFAULT rw
68.02 FORMULA DISPLAY SCALE 4 ENUM 0 : A/B * X + C
1 : A/B * (X+C)
2 : A/(B * X) + C
3 : A/(B * (X+C))
A/B * X + C rw
68.03 COEFFICIENT A DISPLAY SCALE 4 REAL -32768.0000 to 32767.0000 1.0000 rw
68.04 COEFFICIENT B DISPLAY SCALE 4 REAL -32768.0000 to 32767.0000 1.0000 rw
68.05 COEFFICIENT C DISPLAY SCALE 4 REAL -32768.0000 to 32767.0000 0.0000 rw
68.06 HIGH LIMIT DISPLAY SCALE 4 REAL -32768.0000 to 32767.0000 0.0000 rw
68.07 LOW LIMIT DISPLAY SCALE 4 REAL -32768.0000 to 32767.0000 0.0000 rw
68.08 UNITS DISPLAY SCALE 4 STRING max length is 6 chars rw