EasyManua.ls Logo

Parker AC30 series - Keypad Override

Parker AC30 series
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Reference C-105
AC30 series Variable Speed Drive
Keypad Override
Parameters::Keypad::Keypad Override
These parameters may be used to modify the behaviour of the Display/Keypad.
Parameter Name
No.
Path
Default
Range
Units
Writable
Green LED Force On
1862
Parameters::Keypad::Keypad Override
FALSE
ALWAYS
When TRUE, turns the LED under the RUN key on. It is not possible to force this LED off when the drive is running.
Red LED Force Off
1863
Parameters::Keypad::Keypad Override
FALSE
ALWAYS
When TRUE, turns the LED under the STOP key off. It is not possible to force this LED on when the drive is running.
Disable Keys
1865
Parameters::Keypad::Keypad Override
0000
ALWAYS
Mask to disable the normal operation of the selected keys. The corresponding bits are 2 - UP, 3 - DOWN, 4 - LEFT, 5 - RIGHT, 6 - OK.
The mask is ignored when a parameter is being edited, or when an alert message or password entry is active.
This parameter is not saved.
Key Press
1866
Parameters::Keypad::Keypad Override
NEVER
Indicates which key(s) are pressed on the GKP. The corresponding bits are 0 - STOP, 1 - START, 2 - UP, 3 - DOWN, 4 - LEFT, 5 -
RIGHT, 6 - OK, 7 - SOFT KEY 1, 8 - SOFT KEY 2
Selected Parameter
1867
Parameters::Keypad::Keypad Override
NEVER
Shows the PNO of the parameter selected on the GKP. The value is zero when no parameter is selected, or when a parameter is
being edited.