PREF Name Block Type Range Default ro\rw Notes
93.12 RESTARTING AUTO RESTART BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
93.13 ATTEMPTS LEFT AUTO RESTART INT _ 5 ro Output
93.14 TIME LEFT AUTO RESTART REAL _.x 0.0 s ro Output
93.15 TRIGGER 1 WORD 3 AUTO RESTART WORD 0000 to FFFF 0000 rw
93.16 TRIGGER 1 WORD 4 AUTO RESTART WORD 0000 to FFFF 0000 rw
93.17 TRIGGER 2 WORD 3 AUTO RESTART WORD 0000 to FFFF 0000 rw
93.18 TRIGGER 2 WORD 4 AUTO RESTART WORD 0000 to FFFF 0000 rw
93.19 TRIGGER 1 WORD 5 AUTO RESTART WORD 0000 to FFFF 0000 rw
93.21 TRIGGER 2 WORD 5 AUTO RESTART WORD 0000 to FFFF 0000 rw
94.01 SEQ MODES LOCAL CONTROL ENUM 0 : LOCAL/REMOTE
1 : LOCAL ONLY
2 : REMOTE ONLY
LOCAL/REMO
TE
rw
94.02 REF MODES LOCAL CONTROL ENUM 0 : LOCAL/REMOTE
1 : LOCAL ONLY
2 : REMOTE ONLY
LOCAL/REMO
TE
rw
94.03 POWER UP MODE LOCAL CONTROL ENUM 0 : LOCAL
1 : REMOTE
2 : AUTOMATIC
REMOTE rw
94.04 SEQ DIRECTION LOCAL CONTROL BOOL 0 : FALSE
1 : TRUE
FALSE rw
94.05 REMOTE SEQ LOCAL CONTROL BOOL 0 : FALSE
1 : TRUE
TRUE ro Output
94.06 REMOTE REF LOCAL CONTROL BOOL 0 : FALSE
1 : TRUE
TRUE ro Output
95.01 REMOTE COMMS SEL COMMS CONTROL BOOL 0 : FALSE
1 : TRUE
FALSE rw
95.02 REMOTE SEQ MODES COMMS CONTROL ENUM 0 : TERMINALS/COMMS
1 : TERMINALS ONLY
2 : COMMS ONLY
TERMINALS/C
OMMS
rw