D-239
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
2PREF Name Block Type Range Default ro\rw Notes
114.13 ENABLE DRIVE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.14 STATUS REGEN CNTRL ENUM 0 : INACTIVE
1 : SYNCHRONIZING
2 : SYNCHRONIZED
3 : SUPPLY FRQ HIGH
4 : SUPPLY FRQ LOW
5 : SYNCH FAILED
INACTIVE ro Output
114.15 BRAKE MODE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE rw
114.18 Iq DEMAND REGEN CNTRL REAL -1.5 to 1.5 0.0 rw
114.19 MAX CURRENT REGEN CNTRL REAL 0.0 to 1.5 1.5 rw
114.25 HARDWARE SYNC REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.01 INHIBIT SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.02 THRESHOLD SPD FBK TRIP REAL 0.00 to 300.00 % 50.00 % rw
115.03 DELAY SPD FBK TRIP REAL 0.00 to 300.00 s 10.00 s rw
115.04 TRIPPED SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
117.01 OWN ID FIREWIRE INT _ 99 ro Output
117.02 IRM ID FIREWIRE INT _ 99 ro Output
117.03 NUMBER OF
NODES
FIREWIRE INT _ 0 ro Output
117.04 CYCLE TIMER FIREWIRE INT _ 0 ro Output
117.05 BUS RESETS FIREWIRE INT _ 0 ro Output
117.06 MCAP ADVERTS FIREWIRE INT _ 0 ro Output
117.07 MAX HOPS FIREWIRE INT _ 0 ro Output
117.08 OFFSET (40.69ns) FIREWIRE INT _ 0 ro Output