Parker Hannifin
- 106 – Aries Controller Hardware Installation Guide
Important! — Ensure that all cable shields are properly terminated at both
ends of the cable, utilizing 360 degrees of termination either within a metallic
connector shell (preferred) or with an R-clamp terminating the shield to Earth
ground as close as possible to the end of the cable. In any installation,
improperly terminated cable shields will lead to problematic operation in the
form of hardware, software, and communication lock-ups and intermittent
functioning.
• Again, the machine builder’s primary focus should be on ensuring
operators are kept safe from all hazards.
• Install a Mains filter. The drive/controller requires an EMC mains supply
filter to meet EMC emission requirements. It is recommended that the
drive/controller be mounted on a conductive panel which is shared with
the EMC filters. If the panel has a paint finish, it will be necessary to
remove the paint in certain areas to ensure filters and drive/controller
make a good large-area metal to metal contact between filter case and
panel.
The EMC Mains filter should be mounted either at the enclosure
(preferred) or the power entry point or as close to the drive/controller as
possible.
You must install a filter on both the Motor power mains and Control
power mains if both are used. Use Table 40 and Table 41 to determine
the corre
ct filter for your specific application.
Control Power
Control power is 1 Amp, maximum. Any of the following filters works with all
models of the drive/controller.
Filter Manufacturer
6EP1 (160937-5) Corcom
10EP1 (160937-7)
1,
Corcom
FN2070-10/06 Schaffner
1. Available from Parker: 10 Amp filter—part number 47-016140-01
16 Amp filter—part number 47-017900-01
Table 40 Control Power Filter Selection