Parker Hannifin
Chapter 3 Electrical Installation - 27 -
Outputs—General Purpose
The general purpose outputs are optically isolated and current limited. Both
sides of the MOSFET output structure are brought to the pins to allow
significant flexibility in wiring to different styles of interface.
Description Min Typical Max Units
Turn-on time 2 ms
Turn-off time 1 ms
Working voltage 30 30 VDC
On-time voltage drop
IL 10 mA
0.4 VDC
On-time voltage drop
10 mA < IL 100 mA
4.0 VDC
Load current,
IL (TA 35C)
100 MA
Load current,
IL (35C < TA 50C)
80 MA
Short circuit trip current 200 mA
Note: All parameters are at the connector pin.
Table 14 Outputs—General Purpose Outputs Electrical/Timing Characteristics
Output (Motor) Power
Output Power Ratings
Continuous and peak output power ratings for all Aries Controller models are
listed in Table 15.
Continuous Output Peak Output
Drive Current
(Amps,
RMS)
Shaft Power*
(Watts, max)
Current
(Amps,
RMS)
Shaft Power
(Watts, max)
AR-04CE 3.0 400 9.0 1200
AR-08CE 4.5 750 13.5 2250
AR-13CE 6.3 1300 14.1 3900
* Maximum shaft power rating at 240 VAC
Table 15 Output Power, Continuous and Peak