Loading...
Parker Hannifin
- 28 - Aries Controller Hardware Installation Guide
Output (Motor) Power Connections
Figure 15 shows how to connect the motor cable to the Output Power
connector.
Figure 15 Output Power Connection
Current Parker motor cables are marked with white numbers (1,2, or 3) to
indicate the phase. Connect Motor Phase 1 to U, 2 to V, and 3 to W, and
Motor Safety Earth to the Protective Earth ground connector.
Table 16 contains wiring information for making connections with various
Parker Hannif
in motors.
Phase
Hi-Flex/ PS/
Gemini
Legacy Parker
Hannifin
Legacy MaxPlus
U 1 Red/Yellow Red
V 2 White/Yellow Black
W 3 Black/Yellow Blue
Green/Yellow Green/Yellow Green
Table 16 Wiring to Parker Motors
Warning — You must connect the Motor Safety Earth conductor terminal,
marked with the earth symbol
, to the motor cable’s motor-safety-earth wire
(green/yellow).