Parker Hannifin
- 68 - Aries Controller Hardware Installation Guide
LED Steady Flash Description
Off — No Ethernet link detected
Yellow —
Ethernet link established,
no activity
Ethernet
Link/Activity
— Yellow
Ethernet link established
and active
Off — Ethernet 10Mbps Ethernet Speed
Green — Ethernet 100Mbps
Table 28 Ethernet Status LED Descriptions
If neither RJ-45 Ethernet Status LED is illuminated, the physical Ethernet
connection is faulty.
1. Verify that you are using the correct type of cable. See Ethernet Cable
Specification on
page 40.
2.
Verify that the cable pin out matches the drive’s connector pin out. See
Ethernet Connector on pa
ge 40.
3. Try swapping cables with Ethernet cables you know to be good. Even
cables that do not meet the Ethernet cable specification should cause
the LEDs to illuminate.
4. If the LEDs still do not illuminate, look for Ethernet hardware problems.
Ethernet Network Status LED
If the Ethernet Network Status LED is off, there is no valid Ethernet
communication.
Figure 38 Ethernet Network Status LED