- 26 - Aries User Guide
Warning — You must connect the drive’s protective conductor terminal, marked
with the earth symbol
, to a reliable system Protective Earth.
Warning — The drive’s connector strip terminals have hazardous voltages when
power is applied to the drive, and up to several minutes after power is removed.
Lower voltages may still be present for several minutes after power is removed.
During normal operation, these high voltage terminals must not be accessible to
the user.
Motor Power Fuse Information
Aries drives have no user-serviceable internal fuses. For safety, you must
provide a fuse in each of the AC Mains Motor power input lines. To
determine the proper fuse type and size for your application, see Table 14.
(For fuse recommendations for Control-power input lines, see “Control Power
Supply” on page 31.)
Drive AC Voltage Fuse Style Rating Fuse Type
120 VAC 125 VAC Time Delay 10A RK5 or better
AR-01xx
240 VAC 250 VAC Time Delay 10A RK5 or better
120 VAC 125 VAC Time Delay 10A RK5 or better
AR-02xx
240 VAC 250 VAC Time Delay 10A RK5 or better
120 VAC 125 VAC Time Delay 20A RK5 or better
AR-04xx
240 VAC 250 VAC Time Delay 20A RK5 or better
120 VAC 125 VAC Time Delay 20A RK5 or better
AR-08xx
240 VAC 250 VAC Time Delay 20A RK5 or better
120 VAC 125 VAC Time Delay 30A RK5 or better
AR-13xx
240 VAC 250 VAC Time Delay 30A RK5 or better
AR-20xE 240 VAC 250 VAC Time Delay 40A RK5 or better
AR-30xE 240 VAC 250 VAC Time Delay 40A RK5 or better
Table 14 Motor Power Fuse Information