- 42 - Aries User Guide
Connector Descriptions
Motor Mains Power Connector
The drive’s Mains screw terminal connector provides a connection for AC
Mains power to your drive. (For connection information, see “Input Power” on
page 24.) The connector differs between the two largest Aries models and
the others. Specifications for the connectors follow in this section.
On models AR-01xx through AR-13xx, the Mains connector also serves as a
connector for Control power (C1 and C2) and a power dissipation resistor
(R+ and R–). For more information on these additional connections, see
“Control Power Supply” on page 31 “Regeneration Protection” on page 39.)
This connector is removable.
On models AR-20xE and AR-30xE, the Motor/Power connector serves as the
connector for Motor Mains power (L1, L2, L3, and
), as well as for output
power to the motor (U, V, W, and
) and a DC Link Inductor. For more
information on these additional connections, see “Output Power” on page 28
and “External DC Link Inductor (Optional)” on page 30. This connector is not
removable.
Figure 26 Mains/Input Power Connector
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com