BSP-MT 10-95/D3 45
Technical data
Operating Range
Site Selection frost-free indoor installation in a
non-hazardous environment
Ambient temperature 1,5 to 50 °C (24,7 to 122 °F)
Compressed air inlet temperature 25 to 50 °C (68 to 122 °F)
Max. operating pressure 16 bar
e
Min. operating pressure 5 bare
Medium Compressed air
Fluid group 2
Electrical connection
Mains voltage, standard 230 V, 50-60 Hz
Alternative voltage 115 V, 50-60 Hz and 24 V DC
Protection class IP65
Please note type plate and attached electrical circuit diagram!
Performance details
Type Volumetric
ow¹ in
m3/h
Nominal
pipe
2
1. Upstream
lter
2. Upstream
lter
Downstream
lter
Nominal
Press. in
bare
Nominal
temper.
°C
BSP-MT 10
158 1
AOP025EGFI AAP025EGMI AOP025EGMI
16 50
BSP-MT 15 210 1
AOP025EGFI AAP025EGMI AOP025EGMI
16 50
BSP-MT 20 274 1
AOP025EGFI AAP025EGMI AOP025EGMI
16 50
BSP-MT 25 371 1 1/2
AOP030GGFI AAP030GGMI AOP030GGMI
16 50
BSP-MT 35 484 1 1/2
AOP030GGFI AAP030GGMI AOP030GGMI
16 50
BSP-MT 45 589 1 1/2
AOP035GGFX AAP035GGMX AOP035GGMX
16 50
BSP-MT 60 839 2
AOP040HGMX AAP040HGFX AOP040HGMX
16 50
BSP-MT 75 1129 2
AOP040HGMX AAP040HGFX AOP040HGMX
16 50
BSP-MT 95 1371 2 ½
AOP045IGFX AAP045IGFX AOP045IGMX
16 50
1
. m/h, relating to 1 bara and 20 °C at the compressor suction capacity. Subsequently com-
pressed to 13 bare and 35°C inlet temperature to the dryer at 100 % relative humidity – for
pressure dewpoints of -25 °C and -40 °C.
2
. In accordance with DIN ISO 228 (BSP-P)
Noise emission
Noise level : +3 dB (A)
1
65 – 95 dB(A)
1
.. relative to free  eld measurement, 1 m surr.  eld
Dimensions
Please heed to the dimensional drawings and the according table containing dimensions
and weight on page 53.