In order to avoid the case emptying, the flushing return line to tank must be positioned
by following the same instructions provided for the drain line (pls. refer to “Drain Line
Connection”).
Taking the flushing oil from the motor return line allows the simplification of the hydraulic system; however
it is possible to use an external flushing flow rate source, by means of a dedicated pump.
In the table here below, it is possible to find the recommended flushing flow rate (l/min) according to the
motor size.
FLUSHING FLOW RATE SELECTION
DISPLACEMENT
(cm
3
) MOTOR TYPE CLASS
FROM TO
FLOW RATE
(litre / minute)
MR
A 33 57 5
B 73 110 5
MR / MRE
C 125 190 6
MR / MRE / MRA
MRD / MRDE / MRDA
D 200 400 6
MR / MRE / MRA
MRD / MRDE / MRDA
MRV / MRVE / MRVA
E 350 500 8
F 600 800 10
G 1100 1600 10
H 1600 2100 15
I 2400 3500 20
L 3600 5400 20
MR / MRE / MRA
MRD / MRDE / MRDA
MRV / MRVE / MRVA
M 6500 8200 20
MRT / MRTE / MRTF /
MRTA
P 7100 10800
MRT / MRTE / MRTF
Q 14000 23000
23
In order to get the correct flushing flow rate, according to the return line pressure, a drilled grain with the
appropriate diameter holes dimension has to be used. The holes diameter can be chosen by using the
diagrams here below, in accordance to the pressure difference upstream and downstream of the grain; it
has to be taken into account that the maximum case pressure cannot exceed 5 bars if the motor is equipped
with a standard shaft seal.