Parker Hannifin Corporation
Chelsea Products Division
Olive Branch, MS 38654 USA
16
Bulletin HY25-1650-M1/US
Installation Sketch
NOTES:
1) Strip Wire Ends .25" Prior to Installing in Spade Terminal or Butt Connector (As Necessary)
2) Reference Kit 329076X
Electrical Ground
of Cab or Frame
Accepts .25" Screw
16 AWG Wire, Red
Connect to 12 VDC or 24 VDC
16 AWG Wire, Black
Connect to Ground
2-Wire Shielded
Cable
Run Cable through
Grommet in Firewall
Speed Sensor Extension Cable
328923-10X (10 Ft, Supplied w/E.O.C. Option)
328923-5X (5 Ft, Optional Cable)
(4.9")
(1.8")
Electronic Overspeed
Controller - 329650X
(1.0")
379625
Grommet
Slice Grommet
Insert in Hole
in Firewall
Drill 1" Hole
in Firewall
16 AWG Wire, Blue
16 AWG Wire, Green
Saddle Splice Connector
Supplied by Installer
Run Wires through
Grommet in Firewall
Wire “A” 16 AWG Wire
Supplied by Installer
379243
Speed Sensor
28-P-171
O-Ring
Blue
1
379504
Valve Connector
and Wire Assembly
Red
1
379502 Pressure Switch
120-140 In-Lb
Black
Electrical Ground
of Cab or Frame
Accepts #10 Screw
Electronic Over Speed Control (E.O.C.) Installation
Sketch for 890 Series (Allison) (SK-475)
Owner’s Manual
Electronic Overspeed Control
NOTE: Pre-2005 Connect to J1-6 (TCM) or Wire #106
2005 and Later - Connect 43 (TCM) or Wire #143