43
Start-up procedures
8 Start-up
Instruction book, IQAN-MC3
Prepare for system start
WARNING
Make sure no one is in dangerous proximity to the vehicle to avoid
injuries when it starts.
Prepare for the initial system start as follows:
The engine for the hydraulic systems pump shall be in off position.
Make sure that all connectors are properly connected.
Turn on the control system.
Make sure that voltage is being supplied to all modules, the green diode shall be
illuminated on all modules. Also make sure that master is in contact with all mod-
ules by checking the masters status LED. Error codes are blinked if the master is
not in contact with one or more of the modules.
Make sure the emergency stop is functioning properly.
Start the system
Start the system as follows:
Start the engine for the hydraulic system’s pump, assuming that the above men-
tioned inspections have been carried out and shown correct values.
Calibrate and adjust input and output signals according to the instructions related to
the master menu system and check each and every output function carefully.
In addition to these measures, the machine shall also meet the machine directives
for the country in question.
WARNING
Work on the hydraulics control electronics may only be carried out by trained
personnel who are well-acquainted with the control system, the machine and its safety
regulations.