56
Failure modes
Appendix B
Instruction book, IQAN-MC3
On - active CRET
On - passive CRET
Failure mode Detected Comment
COUT open
CRET open
COUT short circuit to CRET (active)
COUT short circuit to CRET (passive) No influence on function in this state.
COUT short circuit to +BAT Reverse feed *.
No influence on function in this state.
COUT short circuit to -BAT
CRET (active) short circuit to +BAT Detection is limited to this output.
Reverse feed * is not detected.
CRET (active) short circuit to -BAT
CRET+ short-circuit to CRET-
COUT short-circuit to 2
nd
COUT
COUT short-circuit to 2
nd
DOUT
COUT short circuit to 2
nd
CRET/DRET
(active)
No influence on COUT (error detected
on 2
nd
COUT/DOUT).
COUT short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
CRET short circuit to 2
nd
CRET (active)
CRET short circuit to 2
nd
CRET
(passive)
No influence on COUT (error detected
on 2
nd
COUT/DOUT).
Insufficient voltage on +BAT current saturated 75% to 100%.
Insufficient voltage on +BAT, current
saturated < 75%
Failure mode Detected Comment
CRET open
CRET short circuit to +BAT Reverse feed *.
No influence on function in this state.
CRET short circuit to -BAT
CRET short circuit to 2
nd
CRET
(passive)
No influence on function in this state.