16
Mounting the unit
5 Mounting
Instruction book, IQAN- MD3
Leave sufficient room behind the unit to insert connectors. Less than 75 mm
clearance will stress the cabling and distort the seals in the connectors. This can
cause the environmental specification not to be met.
Distance behind the unit.
NOTICE
Take careful consideration when positioning the unit.
Position the unit so there is no risk to be exposed to external heat, e.g. from the
engine or heater.
The best readability will be achieved by positioning the front face of the unit
directly towards the operator.
Extended periods of exposure to direct sunlight can cause an internal temperature
exceeding 75°C which may cause permanent degradation of the LCD display.
NOTICE
Both of the connectors, C1 and C2, must be properly installed in the unit.
If you leave a connector unplugged, the unit will not be sealed.
If unused wire positions in a connector are not closed with the recommended plugs,
the unit will not be sealed.
75 mm
22 mm
48 mm