EasyManua.ls Logo

Parker IQAN-MD3 - Failure Modes for VREF; Failure Modes for VIN; Failure Modes for DIN

Parker IQAN-MD3
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
Failure Modes
Appendix B
Instruction book, IQAN-MD3
Failure modes for VREF
Failure modes for VIN
Failure modes for DIN
Failure mode Effect
1 +VREF Open VIN out of range, will create a VIN error =>
VIN=Predefined error value.
2 -VREF Open VIN out of range, will create a VIN error =>
VIN=Predefined error value.
3 +VREF Short-circuit to -VREF VREF error => VIN out of range, will create a VIN
error => VIN=Predefined error value.
4 +VREF Short-circuited to +BAT VREF error => VIN out of range, will create a VIN
error => VIN=Predefined error value.
5 +VREF Short-circuited to -BAT VREF error => VIN out of range, will create a VIN
error => VIN=Predefined error value.
6 -VREF Short-circuited to +BAT External fuse (if <7.5A) on +BAT blows.
7 -VREF Short-circuited to -BAT Not detected.
Failure mode Effect
1 VIN Open VIN out of range, will create a VIN error =>
VIN=Predefined error value
1
1. Measure is controlled by CAN master and application as a result from the CAN error
message. Turning outputs off is controlled by CAN master unit and therefore delayed
maximum 2 bus cycles.
2 VIN Short-circuited to +BAT VIN out of range, will create a VIN error =>
VIN=Predefined error value
1
3 VIN Short-circuited to -BAT VIN out of range, will create a VIN error =>
VIN=Predefined error value
1
Failure mode Effect
1 DIN Open No effect on module, not detected
2 DIN Short-circuited to +BAT No effect on module, not detected
3 DIN Short-circuited to -BAT No effect on module, not detected