EasyManua.ls Logo

Parker Oildyne 108 Series - Performance Data - AC Motors; AC Motor Performance (HA;HD)

Parker Oildyne 108 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
108/118 Series: AC Motors - HA/HD
Performance Data
Instruction Manual
Oildyne 108/118 and 165/175 Series
Hydraulic Power Units
Bulletin HY22-3210A/US
Parker Hannifin
HPS Division
New Hope, MN 55428 USA
207
(3000)
172
(2500)
0
1
2
3
4
5
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow - lpm (cipm)
.100 Pump
with HA / HD Motor
0
.16
.33
.49
.66
.82
(40)
(30)
(20)
(10)
(50)
207
(3000)
172
(2500)
0
2
4
6
8
10
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow - lpm (cipm)
.190 Pump
with HA / HD Motor
0
.33
.66
.98
1.3
1.6
(80)
(60)
(40)
(20)
(100)
207
(3000)
172
(2500)
0
2
4
6
8
10
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow - lpm (cipm)
.250 Pump
with HA / HD Motor
0
.33
.66
.98
1.3
1.6
(80)
(60)
(40)
(20)
(100)
21
41 62 83 103 124
(300) (1800)(1500)(1200)(900)(600)
1
2
3
4
5
6
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
Output Flow - lpm (cipm)
.327 Pump
with HA / HD Motor
0
.41
.82
1.3
1.6
2.0
(100)
(75)
(50)
(25)
(125)
Performance Data
NOTE: S2 = 5
Maximum recommended ON time for the HA/HD motors is 5 minutes, afterwhich the
motors must be OFF until cooled to ambient temperature

Table of Contents

Related product manuals