EasyManua.ls Logo

Parker PSD1-S - 6 Technical Data; Mains Connection PSD1-S; Control Voltage 24 VDC PSD1-S

Parker PSD1-S
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
18 (20)
192-011004N5 DOC-0002-01-R014 14.08.17 09:41
For further information please refer to Help file.
6.1 Mains connection PSD1-S
Category
Specifications
PSD1-S
PSD1-S_1200
PSD1-S_1300
Mains voltage
3 phase 3* 230 VAC ±10%
30 ... 253 VAC / 50-60 Hz
Single Phase 230 VAC ±10%
30 ... 253 VAC / 50-60 Hz
Input Current
(1AC230V): 6.8 Arms
3AC230V: 1.7 Arms
(1AC230V): 11 Arms
3AC230V: 4.2 Arms
Maximum fuse per device*
Single phase: 8 A / Three phases: 3 A
Fuse Class: gS (gRL), Time-delay
Single phase: 12 A / Three phases: 6 A
Fuse Class: gS (gRL), Time-delay
Earth leakage current
Current on the mains PE
Supply networks
Possible supply networks
*
Circuit breakers for operation according to CE.
Circuit breakers for UL und CSA see
UL Chapter
(see on page 11).
6.2 Control Voltage 24 VDC PSD1-S
Category
Specifications
Voltage operating range
21 - 27 VDC
Ripple
0.5 Vss
Requirement according to
safe low voltage (SELV)
yes (class 2 mains module)
Electric current drain
0.5 A
+ Output current of digital output currents (fed via connectors X17/2, 3)
+ Output current of motor brakes (fed via connectors X51/1 & 2))
+ Current requirements of optional boards
6.3 Size / Weight
Category
Specifications
Controller type
Weight
[kg]
Dimensions
Height x Width x Depth (mm]
PSD1-S_1200
1,33 200 x 50 x 180
PSD1-S_1300
6.4 Environmental requirements PSD1
Category
Specifications
General ambient
conditions
In accordance with EN 60 721-3-1 to 3-3
Climate (temperature/humidity/barometric pressure): Class 3K3
Permissible ambient
temperatures:
Operation
0 to +40 °C Class 3K3
Storage
25 to +70 °C
Transport
25 to +70 °C
Tolerated humidity:
Operation
<= 85% Class 3K3
Storage
<= 95 %
Transport
<= 95 %
(Relative humidity)
Elevation of operating
site
<=1000m above sea level for 100% load ratings
<=2000m above sea level for 1% / 100m power reduction
please inquire for greater elevations
Sealing
Type of protection IP20 according to EN 60 529
Mechanic resonances:
Class 2M3, 20m/s
2
;8-200Hz
Pollution Degree
Degree of contamination 2 in accordance with EN 60664-1 and EN 61800-5-1