Note on exchange of options
Device options must be exchanged in the factory to ensure hardware and software
compatibility.
When installing the device, make sure the heat dissipators of the device receive
sufficient air and respect the recommended mounting distances of the devices
with integrated ventilator fans in order to ensure free circulation of the cooling air.
Make sure that the mounting plate is not exposed to external temperature
influences.
3. Conditions of utilization
In this chapter you can read about:
Conditions of utilization for CE-conform operation .......................................................... 9
Conditions of utilization for UL certification of PSD1-S.................................................. 11
EC declaration of conformity PSD1-S ........................................................................... 14
3.1 Conditions of utilization for CE-conform operation
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2014/30/EU and for electrical
operating devices for utilization within certain voltage limits 2014/35/EU are fulfilled
when the following boundary conditions are observed:
Operation of devices only in the state in which they are delivered.
Contact protection mating plug
In order to ensure contact protection, all mating plugs must be present on the
device connections even if they are not wired.
Instructions for this manual
Please respect the specifications of the manual resp. of the help function,
especially the technical characteristics (mains connection, circuit breakers, output
data, ambient conditions,...).
3.1.1. Mains filter for use in industrial areas
A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the system mains input or separately
for jedes Gerät.
Use of the devices in the industrial area (limit values class C3 in accordance
with EN 61800-3)
The following mains filters are available for independent utilization:
Device:
Limit value class
Motor cable length
Mains filter
Order No.:
PSD1-S
C3
< 10 m
no mains filter
PSD1-S (single phase
supply)
C3
> 10 m
ECP-0001-01
PSD1-S (3-phase
supply)
C3
> 10 m
ECP-0002-01