Installation of the individual drive PSD1-S
28 (109) 192-011006N8 2019-07 09.10.19 09:27
4.2 Mounting and dimensions
Ventilation:
• During operation, the device radiates heat (heat dissipation). Please provide for
a sufficient mounting distance below and above the device (at least 100 mm) in
order to ensure free circulation of the cooling air.
• Please do also respect the recommended distances of other devices.
• Make sure that the mounting plate is not exhibited to other temperature
influences than that of the devices mounted on this very plate.
• The devices must be mounted vertically on a level surface. Make sure that all
devices are sufficiently fixed.
4.2.1. Mounting and dimensions PSD1-S
Mounting:
2 socket head screws M6
Lateral distance of fixing of mounting holes: 50.5 mm
Required mounting distance for heat regulation at the top and below: At least
100mm
Please check regularly the firmness of the screw connection!