Installation of the individual drive PSD1-S
28 (109) 192-011006N8 2019-07 09.10.19 09:27
4.2 Mounting and dimensions
Ventilation:
During operation, the device radiates heat (heat dissipation). Please provide for
a sufficient mounting distance below and above the device (at least 100 mm) in
order to ensure free circulation of the cooling air.
Please do also respect the recommended distances of other devices.
Make sure that the mounting plate is not exhibited to other temperature
influences than that of the devices mounted on this very plate.
The devices must be mounted vertically on a level surface. Make sure that all
devices are sufficiently fixed.
4.2.1. Mounting and dimensions PSD1-S
Mounting:
2 socket head screws M6
Lateral distance of fixing of mounting holes: 50.5 mm
Required mounting distance for heat regulation at the top and below: At least
100mm
Please check regularly the firmness of the screw connection!