192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07 09.10.19 09:27 29 (109)
4.3 Connector overview PSD1-S
In this chapter you can read about:
• Front view (PSD1-S) ................................................................................................................. 29
• View from below (PSD1-S) ....................................................................................................... 30
• View from above (PSD1-S) ....................................................................................................... 30
4.3.1. Front view (PSD1-S)
CAUTION: Risk of electric shock
Caution - Risk of electric shock!
Before wiring or loosening electrical connections please observe the
following:
• Risk of electric shock, disconnect power before removing cover resp.
disconnect the devices from the mains supply.
• Caution! Dangerous electrical voltage even after turning off the intermediate
capacitors:
Up to 3 minutes with PSD1-S and 10 minutes with PSD1-M after switching off
mains supply, dangerous voltages may still be present.
Please check that no voltages are present (<50 V) at the output terminals DC+
and DC- of PSD1-S: X63/3 & X63/5 and with PSD1-M: Bus HV DC - 3 & 5. rail.
View from above (see page 30)
Status LEDs for the fieldbus
Slot for SD card
(SD card not included in delivery)
Device address higher value half-byte (accept with
power ON)
Device address low value half-byte (accept with
power ON)
Feedback device Male Connector (Resolver (see
page 101), Encoder/Hall (see page 37))
View from below (see page 30)
*
Before connecting a feedback cable, check that the correct feedback system is
configured in the device.
Otherwise, destruction of the feedback system is threatened by overvoltage!