Installation of the individual drive PSD1-S
34 (109) 192-011006N8 2019-07 09.10.19 09:27
* The internal braking resistor is connected via bridge X63/1 and X63/2:
Device protection
By cyclically switching on and off the power voltage, the input current limitation
can be overloaded, which may cause damage to the device.
Wait at least one minute between two switching on processes!
If neither a braking resistor nor a bridge are connected, the intermediate circuit
4.7.1. Mains connection PSD1-S
30 ... 253 VAC / 50-60 Hz
or
Single Phase 230 VAC ±10%
30 ... 253 VAC / 50-60 Hz
1AC230V: 6.8 Arms
3AC230V: 1.7 Arms
1AC230V: 11 Arms
3AC230V: 4.2 Arms
device*
Three phases: 3 A
Fuse Class: gS (gRL), Time-delay
Three phases: 6 A
Fuse Class: gS (gRL), Time-delay
Current on the mains PE (see page 24) (>3,5 mA)
Possible supply networks (see page 24): TN
Circuit breakers for operation according to CE.
Circuit breakers for UL und CSA see
(see page 18, see page 21).
Please observe the notes in chapter “Operating conditions for CE-conform
operation (see page 13)“.
4.7.2. Braking operation PSD1-S
Capacity/ storable
energy
µ
µ
Minimum braking
resistance