Installation of the multi-axis system PSD1-M
50 (109) 192-011006N8 2019-07 09.10.19 09:27
In case of overload / over-temperature of an output, all outputs are deactivated and
reactivated automatically after cooling.
All inputs and outputs do have 24 V level.
Input level:
"0" (low) = Rated Input Voltage 12.5 V
"1" (high= Rated Input Voltage 13.5 V
The digital outputs are free for writing via object 0x2079.0x01 or 0x60FE.0x01 via
fieldbus.
The status of digital inputs can be read via object 0x2070.0x00 or 0x60FD.0x00 .
5.7 Wiring of the digital inputs and outputs
Wiring of digital inputs
Wiring of digital outputs

Table of Contents