Installation of the multi-axis system PSD1-M
58 (109) 192-011006N8 2019-07 09.10.19 09:27
Caution - Risk of electric shock!
Before wiring or loosening electrical connections please observe the
following:
Risk of electric shock, disconnect power before removing cover resp.
disconnect the devices from the mains supply.
Caution! Dangerous electrical voltage even after turning off the intermediate
capacitors:
Up to 3 minutes with PSD1-S and 10 minutes with PSD1-M after switching off
mains supply, dangerous voltages may still be present.
Please check that no voltages are present (<50 V) at the output terminals DC+
and DC- of PSD1-S: X63/3 & X63/5 and with PSD1-M: Bus HV DC - 3 & 5. rail.
P1
Status LEDs
S2 (see page 60)
Modes switch
S3 (see page 60)
Power supply requirements setting
X4 (see page 65)
Digital Inputs / Outputs
X9 (see page 61)
Control Voltage 24 VDC
24 VDC & DC power
(see page 61)
Behind the yellow protective covers you can find
the rails for the supply voltage connection.
24 VDC-Power supply
DC Power Voltage Supply
View from below (see page 59)