Installation of the multi-axis system PSD1-M
60 (109) 192-011006N8 2019-07 09.10.19 09:27
*Display of error numbers by flash sequence
Green LED: Decimal
1 flash = 10; 2 flashes = 20; 3 flashes = 30; ...
Red LED: Single figure
1 flash = 1; 2 flahes = 2; 3 flashes = 3; ...
Adding both values results in the error number.
Display sequence:
• Green LED = OFF, red LED on for 5 s
• Green LED 1 … 9 flashes, depending on the error number.
• Red LED 1 … 9 flashes, depending on the error number.
• Green LED off and red LED off for 1 s).
This sequence repeats until the error is reset.
Meaning of the error numbers
Temperature in the rectifier too high
Braking circuit overloaded
Temperature in the braking resistor too high
Short-circuit in the braking circuit
Voltage offset DC bus too high
Overcurrent at digital output
None or wrong EEPROM - Data
Caution - Risk of electric shock!
High voltage supply may be present even with missing voltage supply (both
5.12.3. S2: Modes switch (Power module)
position
Increased performance by line choke mode
Warning! Operating without line choke can destroy the device.
Acceptance of the switch position when switching on 24 VDC Control
voltage.
5.12.4. S3: Voltage switch (Power Module)
position
voltage