Technical data
96 (109) 192-011006N8 2019-07 09.10.19 09:27
8.2 PSD1-M: Multi-axes system
In this chapter you can read about:
• Mains Connection Power module PSD1-M_P010 without line choke ........................................ 96
• Mains connection Power module PSD1-M_P010 with line choke .............................................. 96
• Mains Connection Power module PSD1-M_P020 without line choke ........................................ 97
• Mains connection Power module PSD1-M_P020 with line choke .............................................. 97
• Output data servo modules PSD1-M 3*400 VAC ...................................................................... 98
• Output data of the PSD1-M power output stages ...................................................................... 98
• Control voltage 24 VDC PSD1-M_P (mains module) ................................................................ 99
• Braking operation PSD1-M ....................................................................................................... 99
• Dynamic braking module .......................................................................................................... 99
• Size / Weight PSD1-M ............................................................................................................ 100
8.2.1. Mains Connection Power module PSD1-M_P010 without line choke
device
Measure for line and device protection:
UL listing (DIVQ) fuses
Manufacturer: ABB, Stotz-Kontakt GmbH (E212323)
Model No.: S203UP-K, 1 fuse
480 VAC, 3-phase, 25 A, operating temperature 55 °C
8.2.2. Mains connection Power module PSD1-M_P010 with line choke
Increased power by means of a line choke (see page
87
)
PSD1-M_P010 with line
choke
device
Measure for line and device protection:
UL listing (DIVQ) fuses
Manufacturer: ABB, Stotz-Kontakt GmbH (E212323)
Model No.: S203UP-K, 1 fuse
480 VAC, 3-phase, 25 A, operating temperature 55 °C
Current on the mains PE (see page 24) (>3,5 mA)
Possible supply networks (see page 24): TN
The specified performance data are only valid in connection with line choke
IND-0001-02 (see page 87).