The table below contains information on the triggers available:
Designation Description
Level Measurement is started/stopped on exceeding or
dropping below a limit value
Window Measurement is started/stopped on exceeding or
dropping below one of two limit values for a defined
measuring range
Time Measurement is started/stopped at a defined mo-
ment of time
External Measurement is started/stopped on transition of a
digital signal from High to Low
Measurement is started/stopped on transition of a
digital signal from Low to High
Channel warn-
ing value
Measurement is started/stopped when defined
warning values occur
Channel alarm
value
Measurement is started/stopped when defined
alarm values occur
The following methods are available in the Switch function area:
Designation Description
NCLS (Opener) 0 = Active-Low:
Output is < 0.2 V (closed)
1 = Active-High:
Output is dead (open)
NOPN (Closer) 1 = Active-High:
Output is dead (open)
0 = Active-Low:
Output is < 0.2 V (closed)
234
The Parker Service Master CONNECT V1.0/04/20