Parker Hannifin S.p.A S.B.C. Division SLVDN User’s Manual
Page 118 of 181
Pr188=Pr35, (monitor torque) has in escape 4,096V when Pr35 is equal to pick current,
if Pr19=100% [with Pr189=0].
In other cases:
Pr188=Pr…, range in escape ±512 counts as ±4,096V. Therefore if the parameter to
monitor necessity more counts, is necessary to attribute, to Pr189, a such
value to bring back the scale of reading of the parameter within 512 counts:
2
Pr189
.
10.8.9. Master reference
There are three different type of master reference:
- Encoder ref.
-
Reference on digital bus via CAN (see “encoder CAN”)
-
Frequency/direction ref.
The type of reference signal must be connected to the relative connector (see par. “frequency
input/output connection”).
Each reference has a input counter, that encoder signal is calculated on every edge of A and B
signal. The counter of the motor position increases 4096 imp/revolution. It’s possible to set
the relation between master and slave with multiplicative and divisor factors. The encoder ref.
from IN2/IN3 can be set as frequency/direction input type or as input in quadrature (b42.4
and b42.5).
b70.9
Master
speed
d
dt
Pr159
Pr157:156
Pr67:66
Pr154
Pr155
Pr53
Pr52
X2
X1
Reference multiplier
encoder IN
Counter encoder
IN
Counter CAN
input
Master speed
Reference divider encoder IN
Reference CAN
divider
reference CAN multiplier
Encoder
input
b42.5
encoder
Encoder
CAN input
d
dt
Pr54
Pr216
Pr215:214
Pr212
Pr213
IN2/IN3
counter Fre/dir
Master speed
Reference Fre/dir
divider
Freq/Dir
Quadra.
b42.4
Freq/dir – Quadrature
Reference Fre/dir multiplier
b70.13
d
dt
Master reference
(operative mode)