EasyManua.ls Logo

Parker SLVD7N - Page 167

Parker SLVD7N
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin S.p.A S.B.C. Division SLVDN User’s Manual
Page 167 of 181
ENTRY DESCRIPTION
Sub-Index 0
Description number of entries 3
Entry Category Mandatory
Access ro
PDO Mapping No
Value Range 3
Default Value No
Sub-Index 1
Description Position setpoint in counts
the first parameter of ip function fip(x1, ..
xN)
Entry
Category
Mandatory
Access rw
PDO Mapping Possible
Value Range INTEGER32
Default Value No
Sub-Index 2
Description Velocity setpoint in counts/sec
the second parameter of ip function fip(x1, ..
xN)
Entry
Category
Optional
Access rw
PDO Mapping Possible
Value Range INTEGER32
Default Value No
Sub-Index 3
Description Velocity setpoint in rpm
the 3-rd parameter of ip function fip(x1, ..
xN)
Entry
Category
Optional
Access rw
PDO Mapping Possible
Value Range INTEGER32
Default Value No

Table of Contents