20.Appendix G: External capacitor
In the terminal block X7 there are positive and negative poles of the intermediary DC circuit
of the drive. Only for some models it’s possible to connect the external capacitors, to storage
(all or part) of the kinetic energy of the motor instead of to use the braking resistor.
Additional external capacitor:
supply
model
1-phase 3-phase
SLVD1N No permitted
SLVD2N No permitted
SLVD5N No permitted
SLVD7N No permitted
SLVD10N No permitted 2200µF, 450V
SLVD15N
No permitted
2200µF, 450V
SLVD17N
No permitted
2200µF, 450V
Type of capacitor : Itelcond AYX-HR222X450DC1 or similar.
Connections:
use only stranded copper wire rated for 60/75°C, minimum 300V
max length : 30cm
minimum section : 4mm
2
(AWG10)
keep the cables of two poles +/- near (stranded if it’s possible) for to minimize the area of