Parker Hannifin S.p.A S.B.C. Division SLVDN User’s Manual
Page 43 of 181
RJ11
X22 (II axis) - X23 (III axis)
1
TX
2 CK
3 CLOCKOUT
4 +5V
5 0V
6 RX
The connection of the additional axes must respect the following specifications:
- the second axis
must be connected to the X22 connector;
- the third axis
must be connected to the X23 connector.
Below, it’s showed an example of connections: